Set aside the screws and washers for use when you replace the bracket or screen.
Unscrew the screws that are attached the fan screen.
Be sure not to loosen any other nut or screw.
Caution:
Remove the fan from the chassis until you can see the quick disconnect device
inside the right hand side of the chassis.
Disconnect the fan from the inside of the chassis and remove the fan.
Reconnect the fan and place it into the
chassis.
Carefully align the holes on the bracket or
screen with the holes in the chassis.
Replace the screws and washers. Do not over
tighten!
Reinsert the chassis into the rack and secure
it.
Reinsert the modules into the chassis.
Reconnect the power cable and turn on power to the unit.
Quitar y cambiar los ventiladores, si es necesario.
Si un ventilador se estropea, se debe quitar y cambiar.
Desenchufar el cable de alimentación. Si la unidad tiene instalada una UPS,
apagar apretando los botones "ON" y "OFF" del panel delantero de la UPS
(consultar la documentación de la UPS).
Advertencia:
módulo UPS instalado, se deben apretar simultáneamente los botones de
encendido (On) y apagado (Off) durante 3 segundos por lo menos.
Q uitar el cable de alimentación de la fuente de alimentación.
Advertencia :
moverse. Podrían producirse lesiones en los dedos.
Si la BayStack 10 Power Supply Unit está instalada en un bastidor para equipo,
quitar los módulos, la UPS y el paquete de baterías, antes de quitar el chasis del
bastidor.
Quitar la tapa del ventilador y la rejilla metálica del lado derecho de la unidad,
dependiendo del ventilador que no funcione.
30
Para apagar de forma manual la BayStack 10 PSU con el
No tocar los ventiladores hasta que no hayan dejado de
9852FA