11.2 SAFETY CIRCUIT
- The door contacts are prewired to a terminal plugwith screw
terminals D2.
- Safety contact ratings: Min. 5VDC - Max. 250VAC 2A
PE =
Connect ground wire
1 & 2 = Connect safety circuit wires
11.3 PREPARATION AND LEARNING OF DOOR PARAMETERS
Carry out only in event of replacement: replace card or motor.
1 DIP-Switch setting has to be copied from the replaced board, see
chapter 7: "DIP-Switches".
2 In case of need adjust the reference switch so, that switch and mag-
net are opposite one each other when the door panels are closed
(clearance between switch and magnet should be 5÷6 mm).
3 The DIP Switch S1/1 (Test Button Operation) must be activated.
4 Set the panels of the car door in closing position. The sliding blocks should brush against the
buffer.
5 Activate the alimentation through the D1 connector as indicated at par.11.1.
Press the LEARN push-button for one second only, immediately after switching on.
6 Now the door must be driven in close direction by Test Drive Button.
7 The door might now run in wrong direction in respect to command. Use that test drive button
which drives the door in close direction and drive until door panels are fully closed (REF SWITCH
LED must be on).
Sujeto a cambios sin previo aviso
EXCELLENCE IN COMPONENTS
3411.32.0100 ed.0
5÷6mm
Subject to change without notice!
GB
Pag.17.78