Installation Manual
AIR-TO-WATER HYDROMODULE + TANK
ADC0309*
Required tools for Installation Works
1 Philips screw driver
2 Level gauge
3 Electric drill
4 Spanner
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully before installation of Air-To-Water Hydromodule + Tank (here after referred to as "Tank Unit").
Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure to use the correct
rating and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the seriousness is classifi ed by the following indications.
Please leave this installation manual with the unit after installation.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classifi ed by the symbols:
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
Carry out test run to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in
instructions. Please remind the customer to keep the operating instructions for future reference.
If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor
contact, poor insulation or over current will cause electrical shock or fi re.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.
Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction.
Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.
Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.
Do not use the hot water produced by the Tank Unit for drinking or food preparation. It may cause illness to the user.
Do not place containers with liquids on top of the Tank Unit. It may cause Tank Unit damage and/or fi re could occurs if they leak or spill onto the Tank Unit.
For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical
circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fi re.
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building regulation codes.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fi re.
This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and fl are nuts. Using such same may cause abnormally high pressure
in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A refrigerant.
Thickness or copper pipes used with R410A must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm.
It is desirable that the amount of residual oil is less than 40 mg/10 m.
When install or relocate Tank Unit, do not let any substance other than the specifi ed refrigerant, eg. air etc mix into refrigerant cycle (piping). Mixing of air etc. will
cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fi re.
F616515-1
5 Knife
6 Measuring tape
8 Multimeter
WARNING
9 Torque wrench
58.8 N•m (5.8 kgf•m)
ENGLISH ................ 1
ESPAÑOL ............... 9
ITALIANO .............. 17
NEDERLANDS ..... 25
PORTUGUÊS ....... 33
............. 41
ČESKY .................... 49
FRANÇAIS ........... 57
DEUTSCH ............ 65
SVENSKA ............. 73
NORSK ................. 81
SUOMI .................. 89
DANSK ................. 97
65 N•m (6.5 kgf•m)
1
Tabla de contenido
loading

Resumen de contenidos para Panasonic ADC0309 Serie

  • Página 9: Hidromódulo Aire A Agua + Acumulador

    Manual de instalación HIDROMÓDULO AIRE A AGUA + ACUMULADOR ADC0309* Herramientas Necesarias para Trabajos de Instalación 65 N•m (6,5 kgf•m) 9 Llave Dinamométrica 1 Destornillador de Estrella 5 Cuchillo 18 N•m (1,8 kgf•m) 117,6 N•m (11,8 kgf•m) 2 Indicador de Nivel 6 Cinta métrica 55 N•m (5,5 kgf•m) 3 Taladro Eléctrico...
  • Página 10 Instale sobre un punto fi rme y sólido el cual pueda sostener el peso del aparato. Si la fi rmeza no es la sufi ciente o la instalación es inadecuada, el aparato se caerá y causará lesiones. No utilice empalmes para el cable de conexión de acumulador ACS/ unidad exterior. Utilice el cable de conexión del acumulador ACS / unidad exterior especifi...
  • Página 11: Vista Frontal

    Accesorios adjuntos Accesorios de no incluido N°. Pieza Cant. Modelo Especifi caciones Fabricante N°. Parte accesoria Cant. N°. Parte accesoria Cant. Actuador electromotórico SFA21/18 AC230V Siemens Cuerpo Válvula Pies ajustables Codo de drenaje 2 vías Válvula 2 vías VVI46/25 Siemens Tipo Analógico RAA20 Termostato...
  • Página 12: Para Perforar Un Hueco En La Pared E Instalar Una Manga De Tubería

    El acumulador ACS está diseñado para la combinación con la unidad exterior Interior de bomba de calor de aire a agua Panasonic. Si se utiliza una unidad exterior 15 mm de otro fabricante en combinación con el acumulador ACS Panasonic, no se garantiza el funcionamiento óptimo y la fi...
  • Página 13 • El requisito mínimo de agua en el sistema es de 30 litros. Si este valor Especifi caciones recomendadas de válvula reductora de presión: - Presión ajustada: 0,35 MPa (3,5 bars) no se puede lograr, instale un deposito de inercia adicional (no incluido). •...
  • Página 14: Conecte El Cable Al Acumulador Acs

    CONECTE EL CABLE AL Conexión con dispositivo externo (opcional) 1. Todas las conexiones deben seguir la normativa de cableado nacional local. ACUMULADOR ACS 2. Se recomienda altamente utilizar piezas y accesorios recomendados por el fabricante para la instalación. ADVERTENCIA 3. La válvula de dos vías debería ser de tipo muelle y electrónico, consulte la tabla “Accesorios de no incluido”...
  • Página 15: Cargar Y Descargar El Agua

    • La alimentación eléctrica 2 del equipo cumple con IEC/EN 61000-3-2. COMPROBAR LA VÁLVULA DE SEGURIDAD d • La alimentación eléctrica 2 del equipo cumple con IEC/EN 61000-3-11, • Compruebe la operación de corrección de la válvula de seguridad d deberá...
  • Página 16: Ajuste El Caudal De Agua Con La Bomba Circuladora

    Pulse los botones SET y SERVICE simultáneamente durante Mantenimiento para el conjunto de fi ltro 5 segundos. 2. Pulse el botón / para seleccionar el menú CAP RAN. 1. Apagar la alimentación eléctrica. 2. Fije las dos válvulas para el conjunto de fi ltro 6 en “CERRAR”. 3.

Tabla de contenido