15 SmartSolution

Check upon receipt that the packaging is undamaged and
complete. If any abnormity is found, contact your supplier.
Table 14: SmartPSUk2 packing list
#
Item
1
SmartPSUk2
2
Key for front door
3
Cable gland reducers
4
Cable
5
Backplate
PSk2 SmartSolution introduces hybrid power solutions to
the PSk2 system.
Using a combination of the SmartPSUk2 and SmartStart the
PSk2 system can be powered by solar, by AC power from a
generator or grid supply or with a mix of solar and AC pow-
er.
The PSk2 controls the SmartSolution components to deliv-
er water depending on power available, time or specific wa-
ter requirements.
To connect PSk2 to an AC 3-phase grid power supply
then a SmartPSUk2 is used
To connect PSk2 to an AC 3-phase generator then a
SmartPSUk2 and SmartStart is used.

15.1 Solar-diesel system sizing considerations

The SmartPSUk2 is able to switch between solar and diesel
as well as blend both power sources, e.g. to obtain a desired
flow rate or pressure irrespective of sunshine.
QTY
It can operate on diesel generators with a constant power
1 unit
rating higher, equal or smaller than the power rating of the
pump motor.
1 unit
The constant power rating of the diesel generator should be
4 units
selected considering the desired flow or pressure.
1 unit
Please use COMPASS to design the correct size of diesel
generator and refer to knowledge base for background in-
1 unit
formation.
LORENTZ SmartSolution supports the following diesel gener-
ator specifications:
380/ 400/ 415 V
50/ 60 Hz
Remote start function (if use of SmartStart is desired)
SmartSolution
79