Warnings and Safety Notice
!
22
- Self-diagnosis and self-treatment can be dangerous. Always consult your doctor in case of questions or doubts.
- If you are pregnant, accuracy may be impacted for body composition analysis, electrodermal activity score, vascular age. Consult your
doctor during pregnancy.
- Misuse of the device can cause injury.
- Do not step on the scale with wet feet. Potential allergic reactions may occur due to contact with materials used in the device.
- The device is not intended to continuously monitor vital signs in critical conditions or where the nature of the variations is such that it
could result in immediate danger to the user.
- The device does not provide alarms.
- Keep away from children and pets. Small parts may be inhaled or swallowed.
- Exposing the device to prolonged lint, dust or light (including sunlight) may reduce its life or damage it.
- Inspect electrodes for warping, surface damage or corrosion and check for any other form of damage.
- Do not use the device if it is damaged. Use of a damaged device could cause injury or equipment failure.
- Do not submerge the scale or any of the components in water.
- Do not try to repair or modify this equipment yourself. No service or repairs should be performed on the device other than the main-
tenance listed in this guide.
- Do not use accessories, detachable parts, or materials not described in the product guide.
- Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result
in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no
closer than 30 cm (12 inches) to any part of the device, including cables specified by the manufacturer. Otherwise, degradation of the
performance of this equipment could result.
- Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If
such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
- Do not interconnect this equipment with other equipment not described in the product guide.
- Follow operational and storage conditions as described in the technical specifications section of this guide. Otherwise, measurement
results may be impacted.
- Avoid using the device on feet with poor skin integrity, such as cuts, wounds or damaged skin.
- No modification of this equipment is allowed.
- The use of medication with anticholinergic agents may impact Nerve Health Score results. Ask your doctor about the medications you
take if you are not sure whether they have anticholinergic properties.
- Drinking alcohol 24 hours prior to taking a measurement may affect the results of the Nerve Health Score.
- Measurement results may be impacted in case of lower limb amputation.
- In case of severe lesions on the feet (such as ulcers), consult your doctor prior to use, as the performance of the measurement may
be impacted.
Technical Specifications
Product Name: Withings Body Pro 2
Model: WBS14
Battery Life: 10 months typical use
Power Source: Four (4) alkaline cells - AAA
Heart Rate Measurement Range: 30 bpm to 230 bpm
Display: Color 2.8 inch LCD screen
Weight Withings Body Pro 2: 2.2kg
Operation time: 30 seconds
Parts in contact with the skin: Glass plate of the scale
Weight Units: Kilogramos (kg), Libras (lb), Stones (st lb)
Weight range: 5kg - 200kg I 11lb - 440lb I 1st - 31 st
Nerve Health Score measurement accuracy: <0.1%
Transport and storage conditions:
-10°C (14°F) — 50°C (122°F)
10% — 90%
86kPa — 106kPa
Maximum altitude: 2000 m
Operation conditions:
5 °C (41 °F) — 35 °C (95 °F)
20 % — 80 %
86kPa — 106kPa
Maximum altitude: 2000 m
IP Protection level:
IP22
Mode of operation: Continuous Operation
Minimum product life: 3 years
Please be aware that the stated 3-year product life of Withings scales
represents a minimum lifespan under standard tested conditions.
Withings products are designed to last: our scales are manufactured
with care, and are provided with continual over-the-air firmware up-
dates to avoid obsolescence. This is why with proper care and usage,
our health products are likely to serve you reliably for much longer than
the minimum product life. In fact, we're proud to share that 50% of our
users are still actively using their Withings scales after 7 years.
Wireless Information
Wireless Specifications
Mode
Frequency Band
Maximum Output Conducted
(MHz)
Power (dBm)
BT LE
2402-2480
5 dBm
WLAN
2412-2462
16 dBm
The wireless communication of the device is supported by BLE,
WiFi and cellular communication. This communication is estab-
lished between the device and the Withings application. The com-
munication between the device and the Withings application is
encrypted through an exchange of a paired key.
The communication latency between the device and the Withings
application takes less than 10 seconds when the device and the
smartphone are less than 16 feet (5 meters) apart.
The communication between the device and the Withings applica-
tion is not modified with sources of interference located within 5
meters. Wireless coexistence has been tested in accordance with
the following standards:
- ANSI C63.27:2017 and,
- AAMI TIR69:2017/(R2020)
Electromagnetic disturbances have been tested in accordance
with the standard ANSI AAMI IEC 60601-1-2:2014.
Europe - EU Declaration of conformity
Withings hereby declares that the device Withings Body Pro 2 is
in conformity with the essential requirements and other relevant
requirements of the applicable EU Directives and Regulations. The
full text of the EU declaration of conformity can be found at: with-
1282
ings.com/compliance
23
EN-US
ES
EN
FR