Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

Enlaces rápidos

POWERFUL SOLUTIONS. GLOBAL FORCE.
L2592
Rev O
Index:
English...............................................................1-2
Français.............................................................3-5
Deutsch .............................................................6-8
Italiano.............................................................9-11
Español .........................................................12-14
Nederlands....................................................15-17
Portuguese....................................................18-20
Greek.............................................................21-23
Finnish...........................................................24-25
...........................................................26-27
........................................................28-29
Russian..........................................................30-32
Repair Parts Sheets for this product are available
from the Enerpac web site at www.enerpac.com, or
from your nearest Authorized Enerpac Service Center
or Enerpac Sales office.
1.0 IMPORTANT RECEIVING
INSTRUCTIONS
Visually inspect all components for shipping damage.
Shipping damage is not covered by warranty. If
shipping damage is found, notify carrier at once. The
carrier is responsible for all repair and replacement
costs resulting from damage in shipment.
SAFETY FIRST
2.0 SAFETY ISSUES
precautions to avoid personal injury or property
damage during system operation. Enerpac cannot be
responsible for damage or injury resulting from unsafe
product use, lack of maintenance or incorrect product
and/or system operation. Contact Enerpac when in
doubt as to the safety precautions and operations. If
you have never been trained on high-pressure
hydraulic safety, consult your distribution or service
center for a free Enerpac Hydraulic safety course.
Failure to comply with the following cautions and
warnings could cause equipment damage and
personal injury.
A CAUTION is used to indicate correct operating or
maintenance procedures and practices to prevent
damage to, or destruction of equipment or other
A WARNING indicates a potential danger that
requires correct procedures or practices to avoid
personal injury.
A DANGER is only used when your action or lack of
action may cause serious injury or even death.
WARNING:
protective gear when operating hydraulic
equipment.
03/09
Read
all
instructions,
warnings
and
cautions
carefully. Follow all safety
Wear
proper
personal
Instruction Sheet
AM-2 / AM-4
PREMOUNTED MANIFOLDS
AM-2 and AM-4 Premounted Manifolds
Designed to operate at 10,000 psi [700 bar], these
manifolds function as split-flow valves to control up to
two (AM-2) or four (AM-4) single-acting cylinders
simultaneously. The valves can be used for shut-off or
metering in hydraulic circuits. All ports 3/8"-18 NPTF.
WARNING: Stay clear of loads supported
by hydraulics. A cylinder, when used as a
load lifting device, should never be used
as a load holding device. After the load
has been raised or lowered, it must always be
blocked mechanically.
WARNING: USE ONLY RIGID PIECES
TO HOLD LOADS. Carefully select steel
or wood blocks that are capable of
supporting the load. Never use a hydraulic
cylinder as a shim or spacer in any lifting or pressing
application.
DANGER: To avoid personal injury
keep hands and feet away from cylinder
and workpiece during operation.
WARNING: Do not exceed equipment
ratings. Never attempt to lift a load
weighing more than the capacity of the
cylinder. Overloading causes equipment
failure and possible personal injury. The cylinders are
designed for a max. pressure of 700 bar [10,000 psi].
Do not connect a jack or cylinder to a pump with a
higher pressure rating.
DANGER: Never set the relief valve to a
higher pressure than the maximum rated
pressure of the pump. Higher settings
may result in equipment damage and/or
personal injury. Do not remove relief valve.
WARNING:
pressure must not exceed the pressure
rating of the lowest rated component in
the system. Install pressure gauges in the
system to monitor operating pressure. It is your
window to what is happening in the system.
The
system
operating
Tabla de contenido
loading

Resumen de contenidos para Enerpac AM-2

  • Página 12: Importantes Instrucciones De Recepción

    L2592 Rev O 03/09 Las hojas de despiece para este producto estan disponibles en la página web de Enerpac en la dirección www.enerpac.com,o en su centro de Asistencia Técnica ó punto de venta Enerpac mas cercano. 1.0 IMPORTANTES INSTRUCCIONES DE RECEPCIÓN...
  • Página 13: Especificaciones

    Un impacto directo puede romperán, lo que causará lesiones personales y daños causar daños internos a las hebras de a la propiedad. Las piezas ENERPAC están diseñadas alambre de la manguera. Aplicar presión a una para encajar debidamente y resistir altas cargas.
  • Página 14 3. Cubrir los adaptadores con cinta de Teflón dando 1-1/2 vueltas (o sellador de rosca similar) dejando la primera rosca completa sin cinta para evitar que entre la selladora en el circuito hidráulico. Apretar los adaptadores con fuerza. PRECAUCIÓN: Las conexiones deben quedar perfectamente ajustadas y sin fugas.
  • Página 26 POWERFUL SOLUTIONS. GLOBAL FORCE. L2592 03/09...
  • Página 27 "-18 (3x) NPTF 3.66 (93) 1.77 (45) 4.33 (110) 1.77 (45) ø1.57 (ø40) "-18 (5x) NPTF 1.18 (30) (20) (70) 2.76 (250) 9.84...
  • Página 28 POWERFUL SOLUTIONS. GLOBAL FORCE. L2592 Rev O 03/09...
  • Página 29 "-18 (3x) NPTF 3.66 (93) 1.77 (45) 4.33 (110) 1.77 (45) ø1.57 (ø40) "-18 (5x) NPTF 1.18 (30) (20) (70) 2.76 (250) 9.84...

Este manual también es adecuado para:

Am-4

Tabla de contenido